• 0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument
  • 0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument
  • 0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument
  • 0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument

0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument

Type: Static Laser
Sample Feeding: Wet Dispersion
Warranty: 2 Years
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument pictures & photos
0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument
US $8,000-12,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Group Corporation
  • Overview
  • Product Description
  • Products Characteristics
  • Product Parameters
  • Applications
Overview

Basic Info.

Meansure Range
0.01-2000um
Optical Path Calibration
Automatic
Flusing Method
Automatic Instrument Flushing
Executive Standard
GB/T 19077-2016/ISO 13320:2009
Application
Cement, Ceramics, Pharmaceuticals, Lotion
Reference Particle Size
D10/D50/D90
Measurement Range Option
0.01micron - 2000 Microns
Repeatably Error
<0.5%(Average Particle Size of National Samples
Software
Include with The Analyzer
Testing Report
Automatically Generated After Testing
Testing Speed
< 10 Seconds
Operation Temperature
0-45 Degree
Power Requirements
220V (± 20V), 50Hz - 60Hz
Weight
51kgs
Transport Package
Standard Export Wooden Case
Specification
95X51X53cm / 51kgs
Trademark
NKT
Origin
Shandong, Jinan
HS Code
9031809090
Production Capacity
25/PCS/Month

Packaging & Delivery

Package Size
68.00cm * 51.00cm * 53.00cm
Package Gross Weight
51.000kg

Product Description

Product Description

NKT6100-A is the latest product developed by our company, and has won unanimous praise from our customers since its launch. NKT6100-A adopts the internationally advanced Mie scattering principle and convergent Fourier transform optical path. The high-density probe and full range seamless connection test method ensure the accuracy and repeatability of the test results. A unique wet circulating dispersion system ensures that there is no particle deposition during particle testing and no waste liquid accumulation after testing drainage, ensuring the accuracy of the second test and making the test results more authentic and reliable; At the same time, a pipeline design without residues is adopted to ensure the accuracy of testing different samples.   The superior optical path automatic proofreading system highlights the unique advantages of the NKT6100-A.

 
0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument
 

Products Characteristics

 

Main performance characteristics of NKT6100-A laser particle size analyzer:

★ Advanced optical path design: NKT6100-A uses convergent Fourier transform testing technology to ensure maximum range at the shortest focal length, effectively improving the resolution of the instrument; The unique high-density detection unit enables the 6100-A to have strong small particle testing capabilities, while the high-density detection unit enables the NKT6100-A to have strong full range seamless testing capabilities.

★ Dustproof and shockproof design: The entire instrument is sealed, greatly improving the service life of internal components. The unique suspension structure can effectively avoid the interference of external vibration on the instrument, making the test results more stable and reliable.

★ Automatic alignment: The exclusive combination of mechanical center and optical center technology enables automatic adjustment and positioning of the optical path to be more accurate, reaching the micron level; At the same time, the adjustment speed of the optical path is faster, and the adjustment can be completed in up to 15 seconds. The self developed automatic alignment system consists of a stepper motor, a precision guide rail, a precision controller, and a software system. The minimum step distance is 0.2 micrometers, ensuring that the focus of the laser beam always passes through the center of the detector, improving the accuracy of test results and the repeatability of testing. The automatic alignment system is a standard configuration for all types of Nike Laser Particle Sizers.

★ Intelligent fully automatic operation mode: The software realizes one-button operation, including automatic water feeding, automatic sample injection, automatic testing, and automatic cleaning. The entire testing process achieves one-button fully automatic operation, which is convenient and fast to use.

★ Unique micro circulation system: The entire dispersion circulation system has been optimized and designed. When the dispersion medium is greater than 120 ml, it can be circulated for testing, truly achieving micro circulation testing; All joints adopt a quick insertion and quick tightening design, which can replace all pipes in a short time; The optimized design ensures that there is no waste residue after drainage, ensuring the accuracy of the next test results.

★ Ultra wide range: NKT6100-A range reaches 0.0 1 μ m~1250 μ m/0.01-2000um.

★ Ultrasonic anti dry burn: NKT6100-A is equipped with 100W high-power ultrasound, and has ultrasonic anti dry burn function.

★ Misoperation protection: NKT6100-A has a self-protection function, which does not respond to some misoperations that may damage the instrument, greatly reducing the damage caused by human misoperations.

★ Dew point measurement: Misting in the sample window can affect the accuracy of the measurement, and such test results have no practical significance. NKT6100-A has a foggy point measurement system installed, and once fogging occurs, the software will automatically prompt.

★ Bubble free design: The new design prevents bubbles from entering the test sample window during the entire test process, avoiding bubble interference (we exclusively own the bubble free function technology).

★ Sample free design: The instrument pipeline and drainage structure have been optimized to ensure that there is no residual liquid accumulation in the instrument pipeline and circulating pump, avoiding the impact on the next test data; The dry test was also carried out with a residue free design.

★ Sample window quick-change device: A newly designed sample window quick-change device makes it easier and faster to replace the sample window (the sample window disassembly process can be completed in 10 seconds).

0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument

Product Parameters

                Specifications:

Measuring principle: full range laser diffraction NKT6100-A
Particle size range: 0.01 μ m -1250 μ m/  0.01-2000um
Detection system:  90 channel uniform cross and area compensation multi-directional laser array
Accuracy error:
<0.5%(Average Particle Size of National Standard Samples)
Repeatably error:
<0.5%(Average Particle Size of National Standard Samples)
No air bubbles:
With a bubble free design, data is more accurate without bubble interference
Misoperation protection: The instrument has a self protection function for misoperation, and the instrument does not respond to misoperation
Laser parameters: Imported fiber output high-power laser λ= 635nm,  p>5mW
Optical path calibration: Automatic calibration of optical path
Ultrasound: Frequency: f=40KHz, power: p=100W, time: freely adjustable; Equipped with ultrasonic anti dry burning
Circulation, mixing: Integrated design of circulation and mixing, rotational speed: 100-33950rpm, rotational speed adjustable
Circulating flow rate: Rated flow: 0-30L/min Adjustable rated power: 25W
Sample cell: Self designed boiling type sample cell with better dispersion effect, capacity: 190-600mL, can be tested normally
Micro injection: The instrument can be equipped with a micro automatic testing device, and 10 ml can be recycled for testing (optional)
Fog warning: When the sample window reaches the fogging condition, the instrument will issue a fog warning
Testing speed: <1min/time (excluding sample dispersion time)
Appearance size: 95x50x50cm
Instrument weight:  53kgs

Applications

The wet particle sizer is widely used in cement, ceramics, pharmaceuticals, lotion, coatings, dyes, pigments, fillers, chemical products, catalysts, drilling mud, abrasives, lubricants, pulverized coal, silt, dust, cells, bacteria, food, additives, pesticides, graphite, photosensitive materials, fuels, ink, metal and non-metallic powders, calcium carbonate, kaolin, coal water slurry and other powdery materials.

0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument pictures & photos
0.01-2000 Um Wet Dispersion Auto Laser Shampoo Test Particle Size Analysis Instrument
US $8,000-12,000 / Piece
Min. Order: 1 Piece
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory, Group Corporation
Management System Certification
ISO 9001, ISO 20000, QC 080000, GMP, BSCI, ISO 10012
OEM/ODM Availability
Yes