0.1-1000um Intelligent Automatic Wet Laser Particle Size Analyzer for Ceramics/ Pharmaceuticals/ Lotion/Coatings/Dyes,

Product Details
Customization: Available
Type: Static Laser
Sample Feeding: Wet Dispersion
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Group Corporation
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 20000, QC 080000, GMP, BSCI, ISO 10012
OEM/ODM Availability
Yes
  • 0.1-1000um Intelligent Automatic Wet Laser Particle Size Analyzer for Ceramics/ Pharmaceuticals/ Lotion/Coatings/Dyes,
  • 0.1-1000um Intelligent Automatic Wet Laser Particle Size Analyzer for Ceramics/ Pharmaceuticals/ Lotion/Coatings/Dyes,
  • 0.1-1000um Intelligent Automatic Wet Laser Particle Size Analyzer for Ceramics/ Pharmaceuticals/ Lotion/Coatings/Dyes,
  • 0.1-1000um Intelligent Automatic Wet Laser Particle Size Analyzer for Ceramics/ Pharmaceuticals/ Lotion/Coatings/Dyes,
  • 0.1-1000um Intelligent Automatic Wet Laser Particle Size Analyzer for Ceramics/ Pharmaceuticals/ Lotion/Coatings/Dyes,
Find Similar Products
  • Overview
  • Product Description
  • Products Characteristics
  • Product Parameters
  • Applications
  • Company Profile
Overview

Basic Info.

Model NO.
NKT5500-H
Warranty
2 Years
Meansure Range
0.1-1000um
Optical Path Calibration
Automatic
Flusing Method
Automatic Instrument Flushing
Executive Standard
GB/T 19077-2016/ISO 13320:2009
Application
Cement, Ceramics, Pharmaceuticals, Lotion,
Reference Particle Size
D10/D50/D90
Measurement Range Option
0.1 Micron - 1000 Microns
Repeatably Error
<0.5%(Average Particle Size of National Standard
Software
Include with The Analyzer
Testing Report
Automatically Generated After Testing
Testing Speed
< 10 Seconds
Operation Temperature
0-45 Degree
Weight
38kgs
Power Requirements
220V (± 20V), 50Hz - 60Hz
Transport Package
Standard Export Wooden Case
Specification
89X51X53cm / 51kgs
Trademark
NKT
Origin
Shandong, Jinan
Production Capacity
25/PCS/Month

Packaging & Delivery

Package Size
68.00cm * 51.00cm * 53.00cm
Package Gross Weight
51.000kg

Product Description

 

Product Description

Features: 

NKT5500-H is the latest product developed by our company, which has won the unanimous praise of customers since it came into the market. Nkt5500-H adopts the most advanced Mie scattering principle and converging Fourier transform optical path. High density probe and full range seamless connection test method ensure the accuracy and repeat-ability of the test results. The unique wet circulation and dispersion
system ensures no particle deposition during particle testing and no waste liquid accumulation after test drainage, which ensures the accuracy of the second test and makes the test results more authentic and reliable. At the same time, the pipeline design without residue is adopted to ensure the accuracy of testing different products. The superior optical automatic proofreading system shows the unique advantages of NKT5500-H.

0.1-1000um Intelligent Automatic Wet Laser Particle Size Analyzer for Ceramics/ Pharmaceuticals/ Lotion/Coatings/Dyes,

Products Characteristics

1. Advanced optical path design: NKT5500-H adopts the converging Fourier transform testing technology to ensure the maximum range in the shortest focal length, effectively improving the resolution of the instrument; the unique high-density detection unit enables NKT5500-H to have super small particle testing ability; the high-density detection unit enables NKT5500-H to have super full range seamless testing ability, and The

high configuration version adopts a dual optical design.
 
2. Dust proof and shock proof design: the whole instrument is sealed, which greatly improves the service life 1of internal components. The unique suspension structure can effectively avoid the interference of external vibration to the instrument, and make the result test more stable and reliable.
 
3. Automatic calibration of optical path in X and Y directions: NKT5500-H exclusively adopts the technology of combining mechanical center with optical center, which makes the automatic adjustment and positioning of optical path more accurate, reaching the micron level; at the same time, the speed of light path adjustment is faster, and the adjustment can be completed within 15 seconds at most.
 
4. Intelligent automatic operation mode: the software realizes one key operation, automatic water inlet, automatic injection, automatic test and automatic cleaning. The whole test process realizes one key automatic operation, which is convenient and fast.
 
5. Unique micro circulation system: the whole dispersive circulation system has been optimized, and the circulating test can be carried out when the dispersing medium is larger than 180 ml, which truly achieves the micro circulation test; all joints are designed with quick insertion and quick screw, and all pipelines can be replaced in a short time; the optimized design ensures that there is no waste residue after drainage, and
ensures the accuracy of the next test result.
 
6. Ultra wide range: the range of NKT5500-H is 0.01 μ m ~ 1000 μ M.
 
7. Ultrasonic anti dry burning: NKT5500-H is equipped with 100W high-power ultrasound, and has ultrasonic anti dry burning function.
 
8. Misoperation protection: NKT5500-H has the function of self-protection and does not respond to some misoperation that may damage the instrument, greatly reducing the damage caused by human error operation.
 
9. Dew point measurement: fogging in the sample window will affect the accuracy of measurement. Such test results have no practical significance. NKT5500-H is equipped with a fogging point measurement system, and the software will automatically prompt once fogging occurs.
 
10.Bubble free design: the new design prevents bubbles from entering the test sample window during the whole test process, and avoids bubble interference (we have exclusive bubble free function technology).
 
11.Sample no residue design: the instrument pipeline and drainage structure are optimized, and there is no residual liquid in the instrument pipeline and circulating pump to avoid the impact on the next test data; the dry test is also designed with no residue.
 
12.Sample window quick change device: the newly designed sample window quick change device makesthe sample window replacement more convenient and fast (the disassembly and assembly process of sample window can be completed in 20 seconds).
 
13.The stability and repeatability meet the standard of Malvern instrument.
0.1-1000um Intelligent Automatic Wet Laser Particle Size Analyzer for Ceramics/ Pharmaceuticals/ Lotion/Coatings/Dyes,
 

Product Parameters

               Specifications:

Measuring principle: full range laser diffraction
Particle size range: 0.1 μ m -1000 μ M (full range test)
Detection system:  70 channel uniform cross and area compensation multi-directional laser array
Accuracy error:
<1%(Average Particle Size of National Standard Samples)
Repeatably error:
<0.5%(Average Particle Size of National Standard Samples)
Laser type:
Imported fiber output high power semiconductor laser λ = 635nm, P >
10MW, service life > 30000 hours
Optical centering system: mechanical center + optical center double positioning full-automatic centering system
Filtering mode:  dual lens filtering technology, Fourier transform lens + filter lens
Concentration range: minimum shading 3%, maximum shading 90% (optical concentration)
Measurement time (typical value) : < 10 seconds
The measurement accuracy: accuracy and repeatability Dv50 are better than ± 0.5% (NIST traceable standard sample)
Measurement method:  SOP can be edited, fully automatic measurement
Ambient temperature:  0 ° C - 45 ° C
Environmental humidity : Environmental humidity 
Power requirements: 220V (± 20V), 50Hz - 60Hz
Executive standard:  GB / T 19077-2016 / ISO 13320:2009
Appearance size: 890mm × 280mm × 335mm
Instrument weight:  51kg

Applications

The wet particle sizer is widely used in cement, ceramics, pharmaceuticals, lotion, coatings, dyes, pigments, fillers, chemical products, catalysts, drilling mud, abrasives, lubricants, pulverized coal, silt, dust, cells, bacteria, food, additives, pesticides, graphite, photosensitive materials, fuels, ink, metal and non-metallic powders, calcium carbonate, kaolin, coal water slurry and other powdery materials.


0.1-1000um Intelligent Automatic Wet Laser Particle Size Analyzer for Ceramics/ Pharmaceuticals/ Lotion/Coatings/Dyes,

Company Profile

0.1-1000um Intelligent Automatic Wet Laser Particle Size Analyzer for Ceramics/ Pharmaceuticals/ Lotion/Coatings/Dyes,

About US:
Jinan Boni Technology Co., Ltd. is a high-tech enterprise engaged in the R&D, production, sales and service of various laboratory instruments and laser instruments and equipment. The company has been highly valued by leaders at provincial, municipal and district levels, and has been listed as a national high-tech enterprise, a software enterprise in Shandong Province and a provincial particle size and shape analysis instrument technology research center, It has profound theoretical research foundation of laser and image particle size distribution measurement and excellent technical innovation ability, has obtained many patents and rich scientific research achievements, and its technical performance and quality have reached the international advanced level.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier