Secured Trading Service

0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment

Jinan Boni Technology Co., Ltd
  • Audited Supplier
  • 4 yrs

Contact Supplier

Product Highlights

  • Advanced Optical Path Design: Focused Fourier transform technology ensures maximum range and improved resolution.
  • 96-Channel Simultaneous Acquisition: All channels collect signals simultaneously for more real and reliable data.
  • Active Feeding System: Special design for pharmaceuticals ensures even feeding of light, low-density samples.
  • Automatic Optical Alignment: One-key automatic centering with 15-second adjustment speed for micron-level accuracy.
  • High Stability Laser Source: High power fiber output laser with constant power and automatic adjustability.
  • Dustproof and Shockproof Design: Sealed structure and unique suspension system protect internal components from vibration.
  • GMP Compliant Software: Includes electronic signatures, permission settings, and unchangeable data tracking.
  • Zero Residual Pipeline: No sample residue remains in the pipeline to prevent interference with next tests.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of 0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment

0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment pictures & photos
0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment pictures & photos
0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment pictures & photos
0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment pictures & photos
0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment pictures & photos
0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment pictures & photos
0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
  • 0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
    0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
  • 0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
    0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
  • 0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
    0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
  • 0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
    0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
  • 0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
    0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
  • 0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
    0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment

Find Similar Products

Product Description

Product Description

Advanced optical path design: NKT2020-L adopts focused Fourier transform test technology to ensure the maximum range in the shortest focal length and effectively improve the resolution of the instrument; the unique arrangement of small probes enables 2020 to have super small particle test ability. The superior automatic alignment system and computer operating system show NKT2020-L humanized design.

High stability optical path optimization: the unique design makes NKT2020-L have the most advanced high stability optical path, it uses high stability and high power fiber output laser, and the excellent configuration makes NKT2020-L have super stability; the main optical path adopts the full closed design, which ensures the long-term test of the instrument in complex environment.
 

96 channels of simultaneous acquisition main board: NKT2020-L took the lead in using 96 channels of simultaneous acquisition main board. All channels collect signals at the same time, which makes the data more real and reliable. Other manufacturers claim that how many times of acquisition per second is a single acquisition for all channels, and the data is not true.

Special feeding system for pharmaceutical industry: NKT2020-L specially developed a special feeding system for pharmaceutical factories. Many medicinal materials with small density, light weight and traditional vibration feeding are difficult to be evenly cut. The newly developed feeding system is changed from passive feeding to active feeding by instruments. Even feeding can ensure the normal test of very light samples.

Unique dry method dispersion system: NKT2020-L dispersion system is optimized based on the French theoretical data, which makes NKT2020-L disperse the dry powder more evenly, super negative pressure ensures the continuity and uniformity of the feed, and effectively avoids the adhesion of the dry powder in the test process.

Detector: NKT2020-L detector adopts a new design of combination of main detector and auxiliary detector, which ensures seamless detection in the whole range of the instrument and makes the test more accurate. The main detector is designed with an automatic centering system, which can realize one key automatic centering of the instrument and highlight the humanized design. At the same time, it can effectively avoid the damage of manual centering on the detector and effectively extend the service life of the instrument.

Dustproof and shockproof design: the whole instrument is sealed, greatly improving the service life of internal components. The unique suspension structure can effectively.avoid the interference of external vibration to the instrument, and make the result test more stable and reliable.

Automatic calibration of optical path: the combination technology of mechanical center and optical center is used exclusively, and the automatic adjustment and positioning of optical path is more accurate, reaching the micron level; at the same time, the optical path adjustment speed is faster and the fastest 15 seconds can complete the adjustment. The self-developed automatic alignment system consists of step motor, precision guide rail, precision controller and software system. The minimum step distance is 0.2 μ m, which ensures that the laser beam focus always passes through the detector center point, and improves the accuracy of the test results and the repeatability of the test.

No residual in the pipeline: after the test, there is no residual sample in the pipeline, which will not interfere with the next test.

Computer controlled feeding: the tester can precisely control the feeding amount of the instrument with the help of the computer.

Software: in line with GMP regulations of Pharmacopoeia, with electronic signature, permission setting, data tracking, data can not be changed and other functions


0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
 

Product Parameters

 

Model: NKT2020-L
Execution standard: ISO 13320-1:1999;GB/T19077.1-2008
Measurement range: 0.1μm -2000μm
Channels number: 76
Accuracy error: <1%
Repeatably error: <1%
Automatic testing: It is the first in China to realize one key automatic test, and all operation instruments are automatically completed without the assistance of customers. It is the first real automatic dry test instrument.
Oil free silent air compressor With dust filtering function to ensure the accuracy of test
Cold dryer Freeze dryer can filter the moisture in the air to ensure the dispersion effect
Misoperation protection The instrument has self-protection function for misoperation, and it does not respond to misoperation.
Laser parameters Imported fiber output high power laser λ = 650nm, > P > 15MW (constant power, automatic adjustable)
Dispersing method High pressure air dispersion
Operation mode Software automatic control operation
Optical alignment Automatic proofreading of optical path
96 channel simultaneous acquisition main board At present, 96 channels of simultaneous acquisition motherboard are used exclusively in China, which makes the data more accurate and more stable.
Latest active feeding system The traditional vibration feeding system is not suitable for the feeding of some new drugs. The newly improved active feeding system can perfectly test all powder samples, and the feeding is even.
Testing speed < 1min / time (excluding sample dispersion time)
volume 980mm*410mm*450mm

Applications

The dry particle size analyzer has a wide range of applications and can be used for particle size testing of solid powders in various industries such as magnetic materials, pharmaceutical powders, cement, powder coatings, chemicals, food, pesticides, electronics, paper making, metallurgy, ceramics, building materials, abrasives, calcium carbonate, talc powder, kaolin, alumina, rare earths, catalysts, foaming agents, fillers, graphite, pigments, and other industries.

0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment

Packaging & Shipping

 




0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment

0.1-800um Dry Dispersion Lab Use Laser Soil Analysis Testing Equipment
About US:

Jinan Boni Instrument and Equipment Co., Ltd. is a high-tech enterprise engaged in the R&D, production, sales and service of various laboratory instruments and laser instruments and equipment. The company has been highly valued by leaders at provincial, municipal and district levels, and has been listed as a national high-tech enterprise, a software enterprise in Shandong Province and a provincial particle size and shape analysis instrument technology research center,It has profound theoretical research foundation of laser and image particle size distribution measurement and excellent technical innovation ability, has obtained many patents and rich scientific research achievements, and its technical performance and quality have reached the international advanced level.

 

About the Supplier

This supplier has been audited by CTI. Verify the report on the official CTI website with ID "QIP-ASR265221". Items marked "verified" are certified.

Watch Video
Watch Video
Jinan Boni Technology Co., Ltd
Jinan Boni Technology Co., Ltd
Jinan Boni Technology Co., Ltd
Jinan Boni Technology Co., Ltd
Jinan Boni Technology Co., Ltd
Jinan Boni Technology Co., Ltd
Jinan Boni Technology Co., Ltd
Jinan Boni Technology Co., Ltd

About Our Factory & Business Background

Address
Rm2504, 3 Building, No2377, Olympic West Road, Jinan, Shandong, China
Terms of Payment
LC, T/T, PayPal, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DDP, CIP, CPT, FCA
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Beijing/Qingdao/Jinan

Our Production Capability & Technical Expertise

Main Products
Laser Cleaning Machine, Laser Welding Machine, Laser Marking Machine, Laser Particle Size Analyzer, Soil Particle Detector, Soil Moisture Temperature Measuring Instrument, Soil Environmental Nutrient Detector, Water Contact Angle Analyzer, Laser Welder, Laser Cleaner

Our Industry Experience & Global Business Record

Export Year
2010-03-01
Main Markets
South America, Eastern Europe, Southeast Asia, Mid East, Western Europe

FAQ

How long does a single test take?
Testing speed is less than 1 minute per time, excluding sample dispersion time.
Is the instrument suitable for pharmaceutical powders?
Yes, it features a special active feeding system designed for medicinal materials with small density and light weight.
What is the accuracy and repeatability error?
The accuracy error is less than 1% and the repeatability error is less than 0.5% (based on average particle size of national samples).
Does the software comply with GMP regulations?
Yes, the software includes electronic signatures, permission settings, and data tracking functions compliant with Pharmacopoeia GMP regulations.
What is the warranty period for this equipment?
The product comes with a 2-year warranty.
How is the optical path calibrated?
It uses an automatic calibration system combining mechanical and optical centers, achieving micron-level accuracy in as fast as 15 seconds.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now