Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution

Product Details
Customization: Available
Type: Static Laser
Sample Feeding: Droplet
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Group Corporation
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 20000, QC 080000, GMP, BSCI, ISO 10012
OEM/ODM Availability
Yes
  • Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
  • Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
  • Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
  • Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
  • Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
  • Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
Find Similar Products
  • Overview
  • Detailed Photos
  • Product Description
  • Application Scenario
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
NKT5200-H
Meansure Range
0.1-270um
Optical Path Calibration
Automatic
Channels Number
54
Executive Standard
GB/T 19077-2016/ISO 13320:2009
Application
Nasal Drug Products/Aerosol Research
Reference Particle Size
D90/D50/D10
Measurement Range Option
0.1micron - 270 Microns
Repeatably Error
<1% (Average Particle Size of National Standard S
Software
Include with The Analyzer
Testing Report
Automatically Generated After Testing
Testing Speed
< 1 Minutes
Operation Temperature
0-45 Degree
Power Requirements
220V (± 20V), 50Hz - 60Hz
Weight
13kgs
Volume
612mm*230mm*325mm
Transport Package
Standard Export Wooden Case
Specification
61X23X32cm / 13kgs
Trademark
NKT
Origin
Shandong, Jinan
Production Capacity
25/PCS/Month

Packaging & Delivery

Package Size
90.00cm * 51.00cm * 46.00cm
Package Gross Weight
68.000kg

Product Description

Wet mode Laser particle size analyzer NKT5200-H (0.1-800um)

Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
 

Detailed Photos

 

Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
 

Product Description

The main characteristics of NKT5200-H laser particle size analyzer are as follows:
1.  Advanced optical path design: NKT5200-H adopts the converging Fourier transform testing technology to ensure the maximum range in the shortest focal length, effectively improving the resolution of the instrument; the unique high-density detection unit enables NKT5200-H to have super small particle testing ability; the high-density detection unit enables NKT5200-H to have super full range seamless testing ability, and The high configuration version adopts a dual optical design.
2. Dust proof and shock proof design: the whole instrument is sealed, which greatly improves the service life 
of internal components. The unique suspension structure can effectively avoid the interference of external vibration to the instrument, and make the result test more stable and reliable.
3.  Automatic calibration of optical path in X and Y directions: NKT5200-H exclusively adopts the technology of combining mechanical center with optical center, which makes the automatic adjustment and positioning  of optical path more accurate, reaching the micron level; at the same time, the speed of light path adjustment is faster, and the adjustment can be completed within 15 seconds at most.
4.  Intelligent automatic operation mode: the software realizes one key operation, automatic water inlet, automatic injection, automatic test and automatic cleaning. The whole test process realizes one key      automatic operation, which is convenient and fast.
5.  Unique micro circulation system: the whole dispersive circulation system has been optimized, and the      circulating test can be carried out when the dispersing medium is larger than 180 ml, which truly achieves the micro circulation test; all joints are designed with quick insertion and quick screw, and all pipelines can be     replaced in a short time; the optimized design ensures that there is no waste residue after drainage, and       ensures the accuracy of the next test result.
6.  Ultra wide range: the range of NKT5200-H is 0. 1 μ m ~ 800 μ M.
7.  Ultrasonic anti dry burning: NKT5200-H is equipped with 100W high-power ultrasound, and has ultrasonic anti dry burning function.
8.  Misoperation protection: NKT5200-H has the function of self-protection and does not respond to some misoperation that may damage the instrument, greatly reducing the damage caused by human error         operation.
9.  Dew point measurement: fogging in the sample window will affect the accuracy of measurement. Such     test results have no practical significance. NKT5200-H is equipped with a fogging point measurement system, and the software will automatically prompt once fogging occurs.
10. Bubble free design: the new design prevents bubbles from entering the test sample window during the whole test process, and avoids bubble interference (we have exclusive bubble free function technology) .
11. Sample no residue design: the instrument pipeline and drainage structure are optimized, and there is no residual liquid in the instrument pipeline and circulating pump to avoid the impact on the next test data; the  dry test is also designed with no residue.
12. Sample window quick change device: the newly designed sample window quick change device makes the sample window replacement more convenient and fast (the disassembly and assembly process of      sample window can be completed in 20 seconds).
13. The stability and repeatability meet the standard of Malvern instrument
Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
Specifications:
Model: NKT5200-H
Execution standard: ISO  13320-1:1999;GB/T19077.1-2008
Measurement range: 0.1-800um
Number of detector channels: 96
Accuracy error: <0.5%  (D50 value of national standard sample)
Repeatably error <0.5%  (D50 value of national standard sample)
Bubble free: With no bubble design, no bubble interference, more accurate data
Misoperation protection: The instrument has self-protection function of misoperation, and the instrument does not respond to misoperation
Laser parameters Imported fiber output high power laser: λ = 635nm, P > 10MW
Optical path calibration: Automatic calibration of optical path



Dispersion
method
Ultrasonic: Frequency: F = 40KHz, power: P = 100W, time: arbitrarily adjustable; with ultrasonic anti dry burning
Circulation
and mixing
Integrated design of circulation mixing, speed: 100-33950rpm, adjustable speed
Circulation
flow
Rated flow: 0-30l / min adjustable rated power: 25W
Sample cell The self-designed boiling sample cell has better dispersion effect, and the capacity is 190-600ml, which can be tested normally
Microinjection The instrument can be equipped with micro automatic test device, and the test can be repeated in 10ml (optional)
Dust proof and shock proof design: The whole machine adopts dustproof and shockproof design
Anticorrosion design (optional) It can be equipped with acid resistance, alkali resistance, oil resistance    (including all solvent oils) and organic solvents (such as acetone, phenol, n-hexane and other organic solvents).





Software
function:

Analysis
mode:
It includes free distribution, R-R distribution, lognormal distribution,        classification by item, etc., which can meet the different requirements of different industries for the statistical methods of sample size
Statistical
methods:
Volume distribution and quantity distribution to meet the different statistical methods of particle size distribution in different industries
Statistical     comparison: It can be used for statistical comparison and analysis of multiple test        results, and can significantly compare the differences of test results of     different batches of samples, samples before and after processing and at different time, which has a strong practical significance for the quality       control of industrial raw materials.
Self DIY
display
template:
Users define the data to be displayed, calculate the percentage according to the particle size, calculate the particle size according to the percentage, or calculate the percentage according to the particle size interval, so as to meet the characterization method of particle size test in different

Software
Function:
  industries. Distance, consistency, interval accumulation, etc
Test report: Test report can be exported to word, Excel, picture (BMP) and text (text)   and other forms of documents, which can be used to view test reports and reference test results in scientific research articles in any situation.
Language
support:
Chinese and English language interface support, can also be embedded in other language interface according to user requirements.
Intelligent
operation
mode:
Real automatic operation without human intervention, no human factors    interference, you just need to add the sample to be tested according to the prompt, the repeat-ability of test results is better.
Operation mode: Computer operation
Testing speed: < 1min / time (excluding sample dispersion time)
Volume: 680*410*450mm
Weight: 35kgs

 

 

Application Scenario

Winner2308 widely used in cement, ceramics, medicines, lotions, paints, dyes, pigments, fillers, chemicals, catalysts, drilling mud, abrasives, lubricants, coal, sediment, dust, cells, bacteria, food additives, pesticides, explosives, graphite, photographic materials, fuel, ink, metal and non-metal powder, calcium carbonate, kaolin, coal slurry and other powdered materials.

Company Profile

 


Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution
 
About US:
Jinan Boni Technology Co., Ltd. is a high-tech enterprise engaged in the R&D, production, sales and service of various laboratory instruments and laser instruments and equipment. The company has been highly valued by leaders at provincial, municipal and district levels, and has been listed as a national high-tech enterprise, a software enterprise in Shandong Province and a provincial particle size and shape analysis instrument technology research center,It has profound theoretical research foundation of laser and image particle size distribution measurement and excellent technical innovation ability, has obtained many patents and rich scientific research achievements, and its technical performance and quality have reached the international advanced level.
 

Packaging & Shipping

Wet Method 0.01-2000um Laser Particle Sizer for Solid Powder Particle Size Distribution

HOT SALE !!  WELCOME TO CONTACT US !

FAQ

Q: How about quality of the goods?

A:All the running products comply with CE standards.

Independent quality inspection team, conducting multiple inspections and random inspections from parts supply to product dispatch.

Well-known third-party testing service available, such as SGS, BV, and TUV, etc.

 

Q: What are your pre- and after-sales services?

A:Timely reply to pre-sales enquiries

Real-time update of manufacturing and shipment status

Contracted third-party maintenance company in over 60 countries

Assured availability of parts supply for 10 years at least

 

Q: Is OEM service available.

A: Most of the running products are available for OEM customization, including logo, package and function, if attainable, customization.

 

Q: How long is the lead time:

A: Generally, the lead time for most stocked products is about 7~15 days, vary by models and production schedule. For those non-stocked products, the manufacturing lead time is around 20 days.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier