Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer

Product Details
Customization: Available
Type: Static Laser
Sample Feeding: Dry and Wet
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory, Group Corporation
Secured Trading Service
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 20000, QC 080000, GMP, BSCI, ISO 10012
OEM/ODM Availability
Yes
  • Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer
  • Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer
  • Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer
  • Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer
  • Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer
  • Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer
Find Similar Products
  • Overview
  • Products Characteristics
  • Product Parameters
  • Company Profile
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Warranty
2 Years
Meansure Range
0.1-360um
Optical Path Calibration
Automatic
Channels Number
54
Executive Standard
GB/T 19077-2016/ISO 13320:2009
Application
Nasal Drug Products/Aerosol Research
Reference Particle Size
D90/D50/D10
Measurement Range Option
0.1micron - 360 Microns
Repeatably Error
<1% (Average Particle Size of National Standard S
Software
Include with The Analyzer
Testing Report
Automatically Generated After Testing
Testing Speed
< 1 Minutes
Operation Temperature
0-45 Degree
Power Requirements
220V (± 20V), 50Hz - 60Hz
Weight
13kgs
Volume
612mm*230mm*325mm
Transport Package
Standard Export Wooden Case
Specification
61X23X32cm / 13kgs
Trademark
NKT
Origin
Shandong, Jinan
Production Capacity
25/PCS/Month

Product Description

Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer
Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer ManufacturerLaser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer ManufacturerLaser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer

Products Characteristics

1. Advanced optical path design: NKT6100-B adopts convergent Fourier transform test technology to ensure maximum range in the shortest focal length, effectively improving the resolution of the instrument; The unique high-density detection unit enables 6100-B to have super-strong small particle testing capability. The high-density detection unit uses NKT6100-B to have super-strong full-scale seamless testing capability.
2. Double optical path design: double optical path design is adopted for the measurement of 0.1 micron, the measurement range is 0.1 micron to 2000 micron, and blue 405 nanometer laser is adopted for the auxiliary laser. (Optional)
3. One-button switch between dry and wet: the switch between dry and wet will be completed automatically by the instrument, and the whole process will be completed within 10s.
4. Automatic Z-direction movement of the main detector: after the dry-wet switching, the optical glass intervention will cause the focal length of the converging light to change. NKT6100-B will automatically adjust the
 main detector according to the different dry and wet methods so that the main detector is always on the focal plane.
5. Large-aperture lens: large-aperture Fourier transform lens, more effective to realize Fourier transform of optical signals, more accurate and more effective.
6. Anti-dry-burning ultrasound: NKT6100B realizes water-free protection of the sample cell to avoid damaging ultrasound; Meanwhile, the ultrasonic power can be adjusted in the range of 0 to 100 watts.
7. dustproof and shockproof design: the whole instrument is designed in a sealed way, which greatly
improves the service life of internal components. The unique suspension structure can effectively avoid the interference of external vibration on the instrument, making the result test more stable and reliable.
8. Strong anti-corrosion design (optional): Acid, alkali, oil (including all solvent oils) and organic solvents (such as acetone, phenol, n-hexane and other organic solvents) can be provided according to the actual needs of customers.
9. Fog Warning: The instrument has the functions of temperature measurement, humidity measurement and water temperature measurement inside the instrument. The three data are displayed on the computer in real time. When the fogging condition is reached, a sample window fog warning prompt will be issued.
    

Product Parameters

Specification model NKT6100-B
Implementation standard ISO 13320-1:1999;GB/T19077.1-2008
Testing range: 0.1-2000um ( Option: 0.01-2000um)
Number of detector channels: Wet mode: 128  Dry mode: 118
Accuracy error: Dry mode: < 1%,  Wet mode: < 1%  (D50 value of national standard sample)
Repeatability error: Dry mode: < 1%, Wet mode: < 0.5%  (D50 value of national standard sample)
No bubble discharge With bubble-free design, data without bubble interference is more accurate.
Misoperation protection The instrument has self-protection function for misoperation, and the instrument does not respond to misoperation.
Laser parameters Imported fiber output high power laser λ= 635nm, p>5mW
Camera lens: Imported Canon lens
Operation mode: One key automatic operation of dry and wet process software
Optical path calibration Automatic optical path calibration



Wet mode

Dispersion method
Ultrasonic: Frequency: f=40KHz, power: p=80W, time: freely adjustable; With ultrasonic anti-dry burning
Circulation and stirring: Integrated design of circulation and stirring with adjustable rotating speed of 100-3950rpm.
Circulation flow Rated flow: 0-10L/min Adjustable rated power: 25W
Sample cell: Self-designed boiling type sample cell has better dispersion effect, and the capacity: 190-600mL can be tested normally.
Shading detection: The instrument has a unique shading real-time detection function to ensure more accurate sample addition.
Microinjection: The instrument can be equipped with micro full-automatic testing device, and 10 ml can be used for cyclic testing (optional)
 Dry mode
Dispersion method
Dispersion: High pressure air dispersion
Feeding mode: Mechanical stepless speed regulation, vibration feeding, software control
Oil free silent air compressor: With dust filtering function, ensure the accuracy of the test
Cold dryer: The freezing dryer can filter the moisture in the air to ensure the dispersion effect








Software function








Software function
Analysis mode: It includes free distribution, R-R distribution, lognormal distribution and statistical model of classification by order, which can meet the different requirements of different industries for the statistical methods of particle size of the tested samples
Statistical methods: Volume distribution and quantity distribution, to meet the different statistical methods of particle size distribution in different industries


Statistical comparison:
It can be used for statistical comparison and analysis of multiple test results, which can obviously compare the differences of test results of different batches of samples, samples before and after processing and different time, and has strong practical significance for the quality control of industrial raw materials


DIY display template:
Users can define the data to be displayed, calculate the percentage according to the particle size, calculate the particle size according to the percentage or calculate the percentage according to the particle size range, so as to meet the characterization of particle size test in different industries. Diameter distance, consistency, interval accumulation and so on.
Test report: The test report can be exported to word, Excel, picture (BMP), text and other forms of documents, which can be used to view the test report in any situation and reference the test results in scientific research articles
Multilingual support: Chinese and English language interface support, and other language interfaces can be embedded according to user requirements.
Intelligent operation mode Real automatic operation without human intervention, no interference for factors, you just need to add the sample to be tested according to the prompt, the repeatability of test results is better.
operator schema Computer operation
Test speed < 1min/ time (excluding sample dispersion time)
 

 

Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer
 

Company Profile

Jinan Boni Technology Co., Ltd. is a high-tech enterprise engaged in the R&D, production, sales and service of various laboratory instruments and laser instruments and equipment. The company has been highly valued by leaders at provincial, municipal and district levels, and has been listed as a national high-tech enterprise, a software enterprise in Shandong Province and a provincial particle size and shape analysis instrument technology research center,It has profound theoretical research foundation of laser and image particle size distribution measurement and excellent technical innovation ability, has obtained many patents and rich scientific research achievements, and its technical performance and quality have reached the international advanced level.

Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer
Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer

Certifications

 

Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer

Packaging & Shipping

Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer

FAQ

 

Laser Particle Size Analyzer Measuring Range Reaches to Particle Size Analyzer Manufacturer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier